dBChaser is being tested with a small group before it opens to everyone. If you've been sent an early-access key, enter it below.
EcoRumble
No microphone connected
Plug in the measurement mic, then tap Start. Allow microphone access when asked.
Tap a figure to change what it shows. Tap the big number or Fast to cycle through Fast, Slow, Impulse, Leq, Max, L1, L5, L10 and L90.
Octave bands 31.5 Hz to 16 kHz, each the sum of its three 1/3-octave bands. Tap a band to read its level.
Tap a band to read its level. Ticks above the bars hold each band's peak.
Z-weighted narrowband spectrum, 32,768-point FFT with Hann window. Tap to read a frequency.
Last two minutes of the selected weighting, sampled every 100 ms. Dashed line is Leq since the last reset.
A screening check of a worker's daily noise exposure against the workplace exposure standard: LAeq,8h 85 dB(A) and LC,peak 140 dB(C). Measure each task the worker does, save it with the hours spent on it per shift, and the tasks combine into the daily exposure.
Tap Reset at the start of each task, measure a typical stretch of it (at least a few minutes, or one full work cycle), then save it.
These are saved with each reading.
While logging, dBChaser also measures back-to-back 1 s, 10 s, 1 min, 5 min, 15 min, 30 min and 1 h periods, with octave bands (1/1 to 1/24) for 1 min and longer. Choose which go in the PDF report (the Periods CSV has them all):
Clips are for listening back to what caused a reading. They aren't calibrated, and they may record voices, so check you're allowed to record where you measure.
Calibration check: fit the calibrator and tap a check. It reads the level for 3 seconds without changing the calibration. Calibrator level is set in Setup.
Rows are saved on this device as they're recorded, so closing the app or a flat battery only loses the interval in progress. The first and last rows are marked "partial" when they cover less than a full interval.
| End | LAeq | LAFmax | LAFmin | LAF1 | LAF10 | LAF90 | LCeq | LZeq | LZpeak | LAImax | Flags |
|---|---|---|---|---|---|---|---|---|---|---|---|
| No rows yet. Start the meter, then Start logging. | |||||||||||
Manual measurements from the meter. Tap Reset to start a reading and Save reading to keep it, with the site details above.
Every session stays on this device until you delete it. Share or save any of them as a CSV.
Start quiet and turn up slowly. On iPhone, sound can come from the earpiece while the microphone is live; a wired or Bluetooth speaker gives a usable level for room measurements.
Daily noise exposure (LAeq,8h), dose and LC,peak against the workplace exposure standard, built from the tasks a worker does in a shift.
Your company name and logo go at the top of every PDF report, in place of the EcoRumble logo. Enter the client and job number with each session on the Logger page.
PNG or JPG. A logo on a transparent or white background looks best on the white report page.
A profile keeps one mic's calibration, response file and channel setting, so you can swap mics without recalibrating each time. While a profile is chosen, calibrating updates it.
Channel details appear while the meter runs.
Input headroom appears here while the meter runs.
Device names appear after microphone access is granted. The app turns off echo cancellation, noise suppression and auto gain so the signal reaches the meter unprocessed.
Fit the calibrator to the capsule, switch it on, wait for the level to settle, then tap Calibrate. The app averages 3 seconds. Calibrate at 94 dB: if the input overloads, the calibration isn't applied.
Linearity check. After calibrating, measure the calibrator at 94 dB, then switch it to 114 dB and measure again. A linear setup reads 20.0 dB apart. This doesn't change the calibration.
Last calibrated: not recorded yet.
Load the mic's calibration file (two columns: frequency in Hz, correction in dB). It corrects every reading: the meter, the logger, the bands and the spectrum. Corrections are limited to ±12 dB so a steep roll-off below 20 Hz can't amplify wind noise.
No file loaded.
A and C weighting run as IEC 61672 digital filters on every sample; Leq, max, min and percentiles come from those filtered signals. Fast and Slow use 125 ms and 1 s exponential time constants, and Impulse a 35 ms rise with a 2.9 dB/s decay. Percentiles (L1, L10, L90) use the Fast level sampled 40 times a second. Peaks are sample peaks of the Z, A or C weighted signal.
Standards. dBChaser's signal processing was tested electrically against the IEC 61672-1:2013 Class 2 acceptance limits at 44.1 and 48 kHz sampling, and met them: A, C and Z frequency weighting, level linearity, Fast and Slow tone-burst response and decay rate, sound exposure level and C-weighted peak. This covers the software only. The complete meter (microphone, device and app) has not been pattern-evaluated or certified, so it is not a certified Class 2 sound level meter.
Choosing a mic. Results are only as good as the microphone. Use a USB measurement microphone specified to IEC 61672 Class 2 or better, with a flat response and its own response file. Podcast and recording mics often have built-in limiting or automatic gain and an uneven response, so they read low on loud sounds and aren't suitable for measurement. Calibrate each mic and save it as a mic profile, and check the device passes the USB signal through unaltered.
Choose what this figure shows.